Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Rev. bras. ortop ; 58(3): 443-448, May-June 2023. tab, graf
Article in English | LILACS | ID: biblio-1449826

ABSTRACT

Abstract Objective We studied the microbiological profile of periprosthetic knee infections treated in a Brazilian tertiary hospital. Methods The study included all patients undergoing revision surgery for total knee arthroplasty (RTKA) between November 2019 and December 2021, with a diagnosis of periprosthetic infection confirmed per the 2018 International Consensus Meeting (ICM) criteria. Results Sixty-two patients had a periprosthetic joint infection (PJI) per the 2018 ICM criteria. Cultures were monomicrobial in 79% and polymicrobial in 21% of cases. The most frequent bacterium in microbiological tissue and synovial fluid cultures was Staphylococcus aureus, observed in 26% of PJI patients. Periprosthetic joint infection with negative cultures occurred in 23% of patients. Conclusion Our results show the following: i) a high prevalence of Staphylococcus as an etiological agent for knee PJI; ii) a high incidence of polymicrobial infections in early infections; iii) the occurrence of PJI with negative cultures in approximately one fourth of the subjects.


Resumo Objetivo Identificar o perfil microbiológico das infecções periprotéticas do joelho tratadas em um hospital terciário brasileiro. Métodos Todos os pacientes submetidos à cirurgia de revisão de artroplastia total do joelho (RATJ), no período compreendido entre novembro de 2019 e dezembro de 2021, e que tiveram o diagnóstico de infecção periprotética confirmado de acordo com critérios do International Consensus Meeting (ICM) 2018, foram incluídos no estudo. Resultados Sessenta e dois pacientes foram diagnosticados com infecção periprotética (IAP) pelos critérios do International Consensus Meeting 2018. Culturas monomicrobianas foram identificadas em 79% e polimicrobianas em 21% dos casos. A bactéria mais frequentemente identificada nas culturas microbiológicas de tecidos e líquido sinovial foi o Staphylococcus aureus, presente em 26% dos pacientes com infecção periprotética. Infecções periprotéticas com culturas negativas ocorreram em 23% dos pacientes. Conclusão Nossos resultados evidenciam: i) alta prevalência de bactérias do gênero Staphylococcus como causadores da IAP do joelho; ii) a alta incidência de infecções polimicrobianas nas infecções precoces e iii) IAP com culturas negativas ocorre em, aproximadamente, um quarto dos pacientes.


Subject(s)
Humans , Male , Female , Postoperative Complications , Prosthesis-Related Infections , Arthroplasty, Replacement, Knee , Injections, Intra-Articular
2.
Rev. bras. ortop ; 58(6): 917-923, 2023. tab, graf
Article in English | LILACS | ID: biblio-1535629

ABSTRACT

Abstract Objective This study assessed the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of serological tests, synovial fluid markers, microbiological tissue culture, and histopathological examination of the periprosthetic membrane in diagnosing periprosthetic knee infection. Methods This study is prospective, and it includes patients undergoing total knee arthroplasty revision surgery from November 2019 to December 2021. The analysis consisted of serological tests (erythrocyte sedimentation rate [ESR], C-reactive protein [CRP], and D-dimer), synovial fluid markers (leukocyte and polymorphonuclear cell counts), periprosthetic tissue culture, and histopathological examination of the periprosthetic membrane of all patients. Results Sixty-two patients had periprosthetic joint infection (PJI) according to the 2018 International Consensus Meeting criteria (infection group), while 22 subjects had no infection. ESR sensitivity and specificity were 83.6% and 45.4%, respectively. CRP sensitivity and specificity were 64.5% and 100%, whereas D-dimer sensitivity and specificity were 78.9% and 25%, respectively. Leukocyte count sensitivity and specificity were 75.6% and 100%, polymorphonuclear cell count sensitivity and specificity were 33% and 100%, respectively. Periprosthetic tissue culture sensitivity and specificity culture were, respectively, 77.4% and 100%. Histopathological examination sensitivity and specificity were 43.7% and 100%, respectively. Conclusions In our study, the total blood cell count in synovial fluid and microbiological cultures of periprosthetic tissues were the most accurate tests for PJI diagnosis. In contrast, polymorphonuclear cell percentage was the least accurate test for PJI diagnosis.


Resumo Objetivo avaliar a sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia dos testes sorológicos, dos marcadores do líquido sinovial, da cultura microbiológica de tecidos e do exame histopatológico da membrana periprotética para o diagnóstico de infecção periprotética do joelho. Métodos estudo prospectivo, com pacientes submetidos à cirurgia de revisão de artroplastia total do joelho no período entre novembro de 2019 e dezembro de 2021. Foi realizado análise do marcadores sorológicos (VHS,PCR e D-dímero), do líquido sinovial (contagem de leucócitos e percentual de polimorfonucleares), cultura de tecidos periprotéticos e exame histopatológico da membrana periprotética de todos os pacientes. Resultados 62 pacientes foram diagnosticados com infecção periprotética do joelho, pelos critérios do International Consensus Meeting 2018 (grupo infecção) e 22 pacientes integraram o grupo não infecção. A sensibilidade e especificidade da VHS foram de 83,6% e 45,4%, respectivamente. Os valores de sensibilidade e especificidade da PCR foram de 64,5% e 100% e as do D-dímero foram de 78,9%% e 25%, respectivamente. A sensibilidade e especificidade da contagem de leucócitos foi de 75,6% e 100%, e a do percentual de polimorfonucleares foi de 33% e 100%, respectivamente. A sensibilidade e especificidade das culturas de tecidos periprotéticos foi de, respectivamente, 77,4% e 100% A sensibilidade do exame histopatológico foi de 43,7% e a especificidade de 100%. Conclusões A contagem total de leucócitos no líquido sinovial e as culturas microbiológicas dos tecidos periprotéticos foram os testes de maior acurácia para o diagnóstico de infecção periprotética em nossa série. O percentual de polimorfonucleares foi o teste de menor acurácia, em nosso estudo, para o diagnóstico de infecção periprotética.


Subject(s)
Humans , Postoperative Complications , Surgical Wound Infection , Biomarkers , Arthroplasty, Replacement, Knee
3.
Acta ortop. bras ; 26(3): 175-178, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-949743

ABSTRACT

ABSTRACT Objective This study addresses functional data, pain, and the reoperation rate in patients undergoing primary total knee arthroplasty (TKA) during which the patella was or was not replaced. Methods Fifty-three knees were included, 18 with the patella replaced and 35 with the patella not replaced. WOMAC and SF-12 scores and knee pain were analyzed preoperatively and 3, 6, and 12 months after TKA. The reoperation rate was also evaluated. Results Both groups presented significant improvement in WOMAC score and pain at all postoperative follow-up appointments. There was no significant difference between the groups in all evaluated variables. Two subjects in the group did not undergo patellar replacement due to complaints of anterior knee pain after arthroplasty. There was no difference between the groups in relation to the reoperation rate. Conclusion Patients receiving patellar replacement during TKA did exhibit significant differences in the rate of reoperation, function, or pain when compared to patients in which the patella was replaced. Level of Evidence III; Cohort study.


RESUMO Objetivo Este estudo confronta dados funcionais, dor e taxa de re-operação de pacientes submetidos à ATJ primária, que substituíram e que não substituíram a patela. Métodos 53 joelhos, sendo 18 com a patela substituída e 35 com a patela não substituída. Womac, SF-12 e dor no joelho foram analisados no pré-operatório e após 3, 6 e 12 meses da ATJ. A taxa de re-operação também foi avaliada. Resultados Ambos os grupos apresentam melhora significativa no questionário Womac e dor em todos os seguimentos pós-operatórios. Não houve diferença significativa entre os grupos em todas as variáveis avaliadas. Dois sujeitos no grupo NÃO foram submetidos a substituição da patela devido a queixas de dor anterior no joelho após a artroplastia. Não houve diferença entre os grupos em relação a taxa de re-operação. Conclusão Pacientes submetidos a substituição da patela na ATJ não obtiveram diferença significativa quanto a taxa de reoperação, função e dor quando comparados aqueles que não substituíram. Nível de evidência III; Estudo Coorte.

4.
Rev. bras. ortop ; 52(5): 549-554, 2017. tab, graf
Article in English | LILACS | ID: biblio-899185

ABSTRACT

ABSTRACT Objective: Opening-wedge osteotomy of the proximal tibia is a widely performed procedure for treating medial gonarthrosis in active patients and in the presence of varus malalignment of the lower limb. The fixation method is controversial, and the use of conventional implants has been abandoned in favor of implants with more modern locking screws. The aim of the present clinical study was to assess the maintenance of the correction achieved in cases wherein fixation was performed using conventional implants., Methods: This retrospective study included 51 patients who underwent opening-wedge high tibial osteotomy wherein fixation was performed using conventional implants (4.5-mm DCP plate and non-locking screws). Radiological findings regarding patellar height, tibial slope, and varus correction postoperatively and after consolidation were analyzed to assess the maintenance of the correction achieved by osteotomy., Results: The mean loss of correction angle, calculated by the difference between the correction angle in the immediate postoperative period and that after consolidation, was 0.92° ± 0.9°. In addition, changes in patellar height determined by the Blackburne-Peel method and in the sagittal slope of the tibial plateau were not significant or clinically relevant. Conclusions: The use of conventional plates and screws is viable in the fixation of opening-wedge high tibial osteotomy because they provide enough stability to maintain the achieved correction until consolidation, without significant changes.


RESUMO Objetivo: A osteotomia em cunha de abertura da tíbia proximal é um procedimento amplamente feito para o tratamento da gonartrose medial em pacientes ativos e na presença de mau alinhamento em varo do membro inferior. O método de fixação é controverso e o uso de implantes convencionais foi substituído pelo uso de implantes com parafusos de bloqueio mais modernos. O objetivo do presente estudo clínico foi avaliar a manutenção da correção feita nos casos em que a fixação foi feita com implantes convencionais. Métodos: Este estudo retrospectivo incluiu 51 pacientes submetidos a osteotomia tibial alta em cunha de abertura em que a fixação foi feita com implantes convencionais (placa de DCP de 4,5 mm e parafusos não bloqueados). Os achados radiológicos referentes à altura da patela, à inclinação tibial e à correção do varo no pós-operatório imediato e após consolidação foram analisados para avaliar a manutenção da correção obtida pela osteotomia. Resultados: A perda de ângulo de correção média, calculada pela diferença entre o ângulo de correção no pós-operatório imediato e após a consolidação, foi de 0,92° ± 0,9°. Além disso, alterações na altura patelar, avaliadas pelo método de Blackburne-Peel, e na inclinação sagital do platô tibial não foram significativas ou clinicamente relevantes. Conclusão: O uso de placas e parafusos convencionais é uma opção viável na fixação da osteotomia tibial alta em cunha de abertura, pois proporciona estabilidade suficiente para manter a correção obtida até a consolidação, sem alterações significativas.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Knee , Osteoarthritis , Osteotomy , Retrospective Studies
5.
Radiol. bras ; 49(2): 69-74, Mar.-Apr. 2016. tab, graf
Article in English | LILACS | ID: lil-780927

ABSTRACT

Abstract Objective: To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. Materials and Methods: Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR technique, and then with a 3D TSE technique, both in the same 1.5 T MRI scanner. The patients underwent knee arthroscopy within the first three days after the MRI. Using arthroscopy as the reference standard, we determined the diagnostic performance and agreement. Results: For detecting anterior cruciate ligament tears, the 3D TSE and routine 2D TSE techniques showed similar values for sensitivity (93% and 93%, respectively) and specificity (80% and 85%, respectively). For detecting medial meniscal tears, the two techniques also had similar sensitivity (85% and 83%, respectively) and specificity (68% and 71%, respectively). In addition, for detecting lateral meniscal tears, the two techniques had similar sensitivity (58% and 54%, respectively) and specificity (82% and 92%, respectively). There was a substantial to almost perfect intraobserver and interobserver agreement when comparing the readings for both techniques. Conclusion: The 3D TSE technique has a diagnostic performance similar to that of the routine 2D TSE protocol for detecting meniscal and anterior cruciate ligament tears at 1.5 T, with the advantage of faster acquisition.


Resumo Objetivo: Comparar o desempenho diagnóstico da técnica tridimensional turbo spin-eco (3D TSE) de ressonância magnética (RM) do joelho na detecção de rupturas meniscais e ligamentares em comparação com o protocolo bidimensional turbo spin-eco (2D TSE). Materiais e Métodos: A sequência 3D TSE foi adicionada ao protocolo de rotina 2D TSE em 38 pacientes que foram submetidos a cirurgia artroscópica do joelho em até três dias após a realização da RM. Usando os achados artroscópicos como referência padrão ouro, foram calculados o desempenho diagnóstico e a concordância entre os protocolos. Resultados: A técnica 3D TSE e o protocolo 2D TSE apresentaram, respectivamente, sensibilidade (93%/93%) e especificidade (80%/ 85%) semelhantes na detecção de rupturas do ligamento cruzado anterior, sensibilidade (85%/83%) e especificidade (68%/71%) semelhantes na detecção de rupturas do menisco medial, assim como sensibilidade (58%/54%) e especificidade (82%/92%) semelhantes na detecção de rupturas do menisco lateral. A concordância intraobservador entre os dois métodos foi de substancial a quase perfeita em todos os parâmetros avaliados para ambos os leitores. Conclusão: A técnica 3D- SE apresentou desempenho diagnóstico semelhante ao protocolo de rotina 2D TSE na detecção de rupturas meniscais e ligamentares em magneto de 1,5 T, com a vantagem de possibilitar uma redução significativa no tempo de aquisição.

6.
Acta ortop. bras ; 22(3): 159-162, 2014. tab, graf
Article in English | LILACS | ID: lil-716241

ABSTRACT

OBJECTIVE: Evaluate safety and reliability of internal fixator for the treatment of intra-articular and periarticular distal femur fractures. METHODS: Retrospective data evaluation of 28 patients with 29 fractures fixed with internal fixator was performed. There was a predominance of male patients (53.5%), with 52% of open wound fractures, 76% of AO33C type fractures, and a mean follow up of 21.3 months. Time of fracture healing, mechanical axis deviation, rate of infection and postoperative complications were registered. RESULTS: Healing rate was 93% in this sample, with an average time of 5.5 months. Twenty-seven percent of patients ended up with mechanical axis deviation, mostly resulting from poor primary intra-operative reduction. There were two cases of implant loosening; two implant breakage, and three patients presented stiff knee. No case of infection was observed. Healing rate in this study was comparable with current literature; there was a high degree of angular deviation, especially in the coronal plane. CONCLUSION: Internal fixators are a breakthrough in the treatment of knee fractures, but its use does not preclude application of principles of anatomical articular reduction and mechanical axis restoration. Level of Evidence II, Retrospective Study. .

7.
Rev. bras. ortop ; 46(1): 27-30, 2011. ilus
Article in Portuguese | LILACS | ID: lil-596351

ABSTRACT

OBJETIVO: Relatar os resultados iniciais com o uso de nova técnica para a fixação de enxerto ósseo em falhas ósseas tibiais não contidas em pacientes submetidos à prótese total de joelho. MÉTODOS: Seis pacientes com deformidade grave em varo do joelho que, após a realização dos cortes e balanço ligamentar, ainda apresentavam falhas ósseas avançando até à margem do corte tibial e que comprometiam a estabilidade do implante, foram submetidos a uma nova técnica de fixação. RESULTADOS: Cinco dos pacientes apresentaram bom resultado clínico, com integração do enxerto em até 12 semanas. Um paciente apresentou complicação clínica com deiscência da ferida e exposição da prótese, evoluindo para a retirada do implante e artrodese do joelho. CONCLUSÃO: A osteossíntese de suporte como método de fixação do enxerto é uma opção viável para o tratamento das falhas ósseas tibiais. A técnica proposta certamente necessita de mais estudos para a sua validação.


OBJECTIVE: To report the initial results from the use of a new technique for fixation of bone grafts in uncontained tibial bone defects in patients undergoing total knee prosthesis implantation. METHODS: Six patients with severe varus deformity of the knee who, after cuts and ligament balancing had been performed, still presented bone deficiencies that reached the edge of the tibial cut and compromised the implant stability, underwent a new fixation technique. RESULTS: Five of the patients had good clinical results, with integration of the graft within 12 weeks. One patient presented clinical complications with wound dehiscence and implant exposure, which evolved to the need for implant removal and knee arthrodesis. CONCLUSION: Support osteosynthesis as a graft fixation method is a viable option for treating tibial bone deficiencies. The proposed technique certainly needs further studies for its validation.


Subject(s)
Humans , Male , Female , Arthroplasty , Bone Transplantation , Knee Prosthesis
8.
Rev. bras. ortop ; 46(supl.1): 44-47, 2011. tab
Article in Portuguese | LILACS | ID: lil-596377

ABSTRACT

OBJETIVO: Estabelecer se há correlação entre o momento da cirurgia e a ocorrência de complicações intra e pós- operatórias no tratamento das fraturas trocanterianas do fêmur no idoso. MÉTODO: Estudo retrospectivo avaliando o histórico de 281 pacientes operados entre 2000 e 2009 no Hospital das Clinicas da FMRP-USP. As variáveis avaliadas foram: sexo, idade, data, mecanismo do trauma, momento da admissão, tipo da fratura, complicações pré e pós- operatórias, tempo entre o trauma e a cirurgia, horário e duração da cirurgia, implante utilizado, Tip Apex Distance (TAD), tempo de hospitalização, re-operações. De acordo com o horário da cirurgia os casos foram divididos em dois grupos: Horário Comercial (7:00 - 17:00) x Horário Plantão (17:01 - 6:59). RESULTADOS: Houve um predomínio de cirurgias no horário comercial, na proporção aproximada de 5:1. O intervalo de tempo médio entre a data do trauma e a cirurgia foi de três dias. Não houve diferença estatística entre os grupos (hora comercial x plantão) relacionada ao TAD médio, tipo da fratura, implante, complicações sistêmicas e mortalidade em um ano. O tempo médio entre o trauma e a cirurgia foi três dias. CONCLUSÕES: Para pacientes que são admitidos ou operados com mais de 24 horas decorridas do trauma, o horário da cirurgia não se mostrou uma variável relevante, no que diz respeito à ocorrência de complicações per operatórias. Em nossa realidade, é preferível realizar a fixação destas fraturas em horário comercial, dispondo de completa infra-estrutura de recursos humanos e técnicos.


OBJECTIVE: This study aimed to verify if there is any relationship between the time of surgery and per operative complications in the treatment of intertrochanteric femoral fractures. METHOD: The records of 281 patients operated between the years of 2000 and 2009 were evaluated retrospectively. The variables taken into account were sex, age, date and mechanism of injury, time of admission, type of fracture (AO classification), pre and post-operative complica- tions, delay between trauma and surgery time, time and duration of surgery, implant used, Tip Apex Distance (TAD), and hospital stay. The cases were divided according with the start time of surgery into two groups: usual working hours (7:00 - 17:00) x non-usual working hours (17:01 - 6:59). RESULTS: Most of the surgeries were performed during working hours, at an approximate ratio of 5:1. The average time between trauma and surgery was three days. There was no statistical difference between groups (working vs. non-working hours) in relation to the average TAD, type of fracture, implant, clinical complications and mortality in one year. CONCLUSIONS: Our study demonstrates that for patients that are not admitted or operated within the first 24 hours from trauma, the time of surgery is not a relevant variable, regarding to per-operative complications. In our reality, there is no reason for operating such patients out of working hours, when all necessary resources are available.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Hip Fractures/surgery , Hip Fractures/rehabilitation , Intraoperative Complications , Surgical Procedures, Operative
9.
Rev. bras. ortop ; 44(6): 468-474, 2009. ilus
Article in Portuguese | LILACS | ID: lil-538060

ABSTRACT

As fraturas do planalto tibial são lesões articulares cujos princípios de tratamento envolvem a redução anatômica da superfície articular e a restauração funcional do eixo mecânico do membro inferior. Contribuem para a tomada de decisões no tratamento dessas fraturas o perfil do paciente, as condições do envelope de tecidos moles, a existência de outros traumatismos associados e a infraestrutura disponível para abordagens cirúrgicas. Para as fraturas de alta energia, o tratamento estagiado, seguindo o princípio do controle de danos, tem como prioridade a manutenção do alinhamento do membro enquanto se aguarda a resolução das más condições de tecidos moles. Já nos traumas de baixa energia, desde que os tecidos moles não sejam um fator adverso, o tratamento deve ser realizado em tempo único, com osteossíntese definitiva. Fixação estável e movimento precoce são variáveis diretamente relacionadas com os melhores prognósticos. Desenvolvimentos recentes, como os implantes com estabilidade angular, substitutos ósseos e imagens tridimensionais para controle intraoperatório, deverão contribuir para cirurgias menos invasivas e melhores resultados.


Tibial plateau fractures are joint lesions that require anatomical reduction of joint surface and functional restoration of mechanical axis of a lower limb. Patient profile, soft tissue conditions, presence of associated injuries and the available infrastructure for the treatment all contribute to the decision making about the best treatment for these fractures. High-energy fractures are usually approached in a staged manner respecting the principle of damage control, and are primarily targeted to maintain limb alignment while the resolution unfavorable soft tissue conditions is pending. Low-energy trauma can be managed on a single-stage basis, provided soft tissues are not an adverse factor, with open reduction and internal f-ixation. Stable fixation and early painless joint movement are related to a better prognosis. New developments as locked plates, bone replacements, intraoperative 3D imaging are promising and will certainly contribute for less invasive procedures and better outcomes.


Subject(s)
Humans , Tibial Fractures/complications , Tibial Fractures/diagnosis , Tibial Fractures/therapy
SELECTION OF CITATIONS
SEARCH DETAIL